Part Number Hot Search : 
EVKIT 20240 7815PI BH6511 DIAMOND 2SD14 ZM33164G RT3P66M
Product Description
Full Text Search
 

To Download TFS420B Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 file: TFS420B.doc
version 1.1 01/99 ______________________________________________________________________________________________________
VI TELEFILTER Filter specification TFS 420 B 1/4 ______________________________________________________________________________________________________
Measurement condition Ambient temperature: 23 C Input power level: 0 dBm Source impedance: 162 || -0,39 pF Load impedance: 162 || -0,39 pF Construction, pin connection and 50 test circuit See page 2 Stability characteristics and packing See page 3 Air reflow temperature conditions See page 4
Characteristics Remark:
Reference level for the relative attenuation arel of the TFS 420 B is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 2 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 420 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo
Data
______________________________________________________________________________________________________ 3 dB max. 5 dB ae = amin Insertion loss (Reference level) ______________________________________________________________________________________________________ 420 MHz fN Nominal frequency _____________________________________________________________________________________________________ 420 MHz Centre frequency fo ______________________________________________________________________________________________________ Pass band ripple fN 10 MHz 1 dB max. 2 dB ______________________________________________________________________________________________________ Relative attenuation arel
typ. value
tolerance / limit
320 MHz ... 340 MHz 60 dB min. 50 dB 365 MHz ... 385 MHz > 40 dB min. 40 dB ______________________________________________________________________________________________________ Operating temperature range - 25 C ... + 75 C ______________________________________________________________________________________________________ - 65 ppm/K Temperature coefficient of frequency TCf ______________________________________________________________________________________________________ Input power level max. 10 dBm ______________________________________________________________________________________________________ *) At the moment we are carrying out tests to check the possibility of guaranteing higher limiting values.
Generated: Checked / approved:
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
version 1.1 01/99 ______________________________________________________________________________________________________
file: TFS420B.doc
VI TELEFILTER Filter specification TFS 420 B 2/4 ______________________________________________________________________________________________________
Construction and pin connection
S 420B L1
1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Output RF Return Output Package Ground Ground Ground Ground Input RF Return Input Package Ground Ground
50 test circut 1
L1 10 4 L2
IN
C1
SAW
C2
OUT
1,2,3,5,6,7,8,9,11,12
50 test circut 2
C1 10 4 C2
IN
L1
SAW
L2
OUT
1,2,3,5,6,7,8,9,11,12
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: TFS420B.doc
version 1.1 01/99 ______________________________________________________________________________________________________
VI TELEFILTER Filter specification TFS 420 B 3/4 ______________________________________________________________________________________________________
Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 30g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes; DIN IEC 68 T2 - 6 90 % to 95 % rel. humidity, 40 C, 10 days; IEC Pub. 68 - 2 - 3
2. Vibration:
3. Damp heat:
4. Resistance to solder heat (Reflow):
260 C for 10 sec;
Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 3000
Tape (all dimensions in mm) W Po Do D1 E : : : : : 16 4 1,5 0,3 0,1 + 0,5
EMBOSSED CARRIER TAPE
Do
Po
P2
1,5 + 0,5 1,75 0,1 7,5 0,1 0,75 2 8 1,5 5,4 7,4 0,05 0,1
P1 13,4
0,1
E Ao F W
F : G (min) : P2 P1 : :
D1 Bo
G
D1(min) : Ao : Bo :
0,1 0,1
COVER TAPE
W2
Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 16,4 +2 22,4 >= 90
C A N
13
0,25
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape.
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: TFS420B.doc
version 1.1 01/99 ______________________________________________________________________________________________________
VI TELEFILTER Filter specification TFS 420 B 4/4 ______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS420B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .